@brianridge22: #groundrod #install #residential #electric #cooltool #jackhammer #driver #electrician #electriciansoftiktok #foryou @milwaukeetool @kleintools #stepbystep

Brian Ridge
Brian Ridge
Open In TikTok:
Region: US
Wednesday 07 December 2022 02:12:02 GMT
1105385
57355
1200
867

Music

Download

Comments

according2dk
Daniel K :
Canadian here, It always blows my mind to see a homes panel on the outside of the house! 🤯. We like to keep them on the inside of our igloos.
2022-12-07 02:29:34
1694
zachduncan84
Zach Duncan :
you cut the rod didn't you?
2022-12-07 02:38:50
343
jwes2699
JoshWesley :
Uhhh I’m pretty sure that’s a water/gas line bonding clamp, not an acorn? Correct me if I’m wrong
2022-12-07 03:07:29
64
joshuat92
Josh! :
Man. They do things different in Cali. That would fail inspection so hard here in WA state. And OR state.
2022-12-07 02:30:00
85
dracoriot4100
DracoRiot4100 :
you need 2 rods, no less than 6' apart unless 1st is less than 25ohms. NEC 250.56/ 250.64/ 250.66
2022-12-07 15:23:28
10
_peterp_
_PeterP_ :
Not a lot of traffic there ? And when someone goes out in the dark to check the breakers then they will impale the rod sticking out
2022-12-07 06:57:27
129
knowiewoahie
Knowie Back :
Here in Ohio it takes 2 hours to drive one of those 😅🔨
2022-12-07 02:30:47
224
firedave6
Dave Dubovsky Jr :
I have never in my life seen a piece of mc to the ground rod. Just run bare solid…..
2022-12-07 06:38:07
164
markmannino500
markmannino500 :
Wrong on so many levels
2022-12-07 03:53:52
15
suprome6
Rome :
isn’t code #4 stranded and 2 ground rods 6 feet apart? i don’t think this will pass in california
2022-12-07 03:03:56
29
nathantownsend06
Little_trips_wa🇦🇺 :
Everything is a hammer if you’re an electrician 😂
2022-12-07 03:15:58
288
elpipas_134
user4227876456809 :
They never go in that easy!!! 😂
2022-12-07 02:32:01
185
paulmazz1
paulmazz1 :
Outside breaker boxes freak me out! In PA they have to be installed on the interior.
2022-12-07 12:01:53
18
ryanjayyy10
ryanjayyy10 :
No USA marking? You just picked the spot and said yah that’s good? Lol
2022-12-07 04:59:46
21
der_kaptain
der_kaptain :
I love your work in tiktok but not today. I have been searching for a ground loop all day long.
2022-12-07 05:24:56
17
bk689
kk :
Even the pyramids had their panels inside…..Ohio
2022-12-07 05:13:43
5
ddp090
DDP :
Do you not test the rod resistance before final connection? 😳
2022-12-07 03:01:22
31
richiericardo15
Richie Sanchez-Mcken :
I did mine a little different. I used 15ft copper wire(no protector, copper wire run down the outside the house) used two ground rounds to meterbase
2022-12-07 15:00:00
39
adizizle
ADiZiZLE :
Why not use #4 solid so you don’t have to put it in flex
2022-12-07 06:34:00
35
kidoblivious
user8790597483941 :
how much did u charge for that job?
2022-12-07 02:35:12
37
b58_gallo
Daniel :
Pretty sure that ground lug needs to be machine threaded
2022-12-07 08:17:14
41
tazjake77
Tazjake7 :
Did you ground the steel cable instead of the copper wire?
2022-12-07 07:40:07
40
deedub007
Darren Williams :
I've got one of those hammers too.
2022-12-07 10:50:12
34
5starrr.alex__
wockst★rz :
First
2022-12-07 02:15:17
36
To see more videos from user @brianridge22, please go to the Tikwm homepage.