@chrisbodenn: Authorized Personnel Only - How to Start and Sync a 400,000 Watt Turbine Hydroelectric Generator#chrisboden #comedyvideo #engineering #mechanical #torque #motor #coupling #big #community #service #puppies #pets #nonprofit #grandrapids #petfood #educational #science #update #project #funny

Chris Boden
Chris Boden
Open In TikTok:
Region: US
Friday 18 July 2025 00:22:48 GMT
483073
27066
698
1957

Music

Download

Comments

willnickolson
willnickolson :
This is what I want to see on the app
2025-07-18 06:54:47
1128
dr.2702
dr.2702 :
what people don't understand is if you connect out of sync the power plant will literally blow up
2025-07-18 07:48:12
1675
user60981132391867
Jon Meacham431 :
that angry gauge living its best life at the beginning just going full bore on its rotation 😂😂😂
2025-07-19 07:04:44
0
elle.mp.20
Elle :
Where does all that power go before you bring it onto the grid?
2025-07-18 03:13:02
109
jnmoonunit
Jnmoonunit :
Done that several times with 50 meg steam turbines. Scary every time
2025-07-18 01:09:58
467
tylorhillman0709
tylorhillman0709 :
angry spinning gauge 😂 me trying to explain things to my boss 🤣
2025-07-18 00:58:01
2650
chaddoan128
chaddoan128 :
Why is that process not automated?
2025-07-18 18:16:45
2
zuli64_citizen
Zuli64 :
Slow in the fast direction
2025-07-18 17:03:11
13
cyrberger
cyrano :
the crazy gauge on the right looks straight outta cartoom
2025-07-19 08:42:33
0
branden_smom
Branden_smom :
I love people that are passionate like this guy about their jobs. fascinating stuff.
2025-07-18 09:32:27
380
supreme.leader85
Supreme Leader :
me, plugs in a Tesla at 250kWh 💀
2025-07-18 07:38:50
0
vipsuperdave
SuperDave :
You'd think they'd at least get a label maker and label everything instead of Sharpie marker. lol
2025-07-18 16:00:14
1
gfarmer7
G.Farmer :
This seems outdated, why not use microcontrollers for quick synchro, optimization and protection
2025-07-18 14:20:05
3
rumrunner81
rumrunner81 :
I remember being a 4th year apprentice with the boss doing a 9MW steam turbine and it's an anxiety inducing experience. similar looking panels and controls. just an angry boiler operator instead of a river
2025-07-18 06:41:49
204
will.i.am778
Will I Am :
Why can’t you use the grid to help sync with the power plant? I kinda understand why it needs to match with magnetic fields and all that but is it possible to pull power from the grid to get that big hunk of copper to match the frequency? Also where are the contacts that connect to the grid. I was stressed watching this sync up. Lol.
2025-07-18 06:45:41
6
keeperofthejellybeans85
Jim ❌️dandy :
Chris Boden - when did you know you had a touch of the tism.
2025-07-18 11:30:34
12
jughead903_2
JugHead903 :
And to think. Google at one site has 36 2.75MW, 13800 volt Cat gensets. At one site.
2025-07-18 02:07:13
125
mr._bhe
Mr. BHE :
I do this every day….
2025-07-18 06:30:25
15
5kunky
Skunky :
Crazy to think we have industrial generators that are 5MW and this plant is .4MW. the Gensets we commonly test are 1MW
2025-07-18 01:33:56
83
yanisirl
Yandalf :
Time for an upgrade to modern sync technology. This stuff is prehistoric
2025-07-18 13:58:33
54
popcorn1109
popcorn9988 :
350kw that's barely one ev 😎
2025-07-18 08:22:45
3
sav3ge666
SAV3GE :
Why is the sync process not automated these days
2025-07-18 13:04:12
4
reactor.cowboy
Reactor Cowboy :
Bro, just put the kW in the bag. Slow in the fast direction.
2025-07-18 19:29:01
17
maxjordan7725
Maxy :
Worked at a hydro plant for awhile when the operator didn't quite sync the generator online it would shake the entire building.
2025-07-19 02:19:05
18
abiroodog
AbiRooDog :
America still in the dark ages 😂
2025-07-18 11:55:31
1
To see more videos from user @chrisbodenn, please go to the Tikwm homepage.