@theplumberlorian: Quick water heater swap 😁🤙 #Plumber #Plumbing #Copper #Soldering #BlueCollar #HandTools #PositiveVibes #DIY #WaterHeater #Work #Home #BlueCollarBoysDoItBetter

The Plumberlorian
The Plumberlorian
Open In TikTok:
Region: US
Sunday 27 February 2022 13:20:00 GMT
46762
702
95
4

Music

Download

Comments

kylerwolf1990
kylerwolf1990 :
I see you always put recirc pumps on your heaters. But How does this recirc pump work if there's no separate line ran?
2022-02-27 13:33:07
7
davidroy450
David Roy :
I would have used new ball valves instead of couplings at the wall
2022-02-27 14:16:34
5
your_captain_colin
Your_Captain_Colin :
Did they not have stove pipe lol it’s only fittings
2022-02-27 14:19:30
5
mikeguglielmo36
Mike Guglielmo :
What happened to the shutoff valves ?
2022-02-27 13:45:06
2
starlord77777777
Star Lord777 :
So no cutoff values on the cold water side? Not good.
2022-02-27 14:27:19
1
austincrawford0310
Acrawford :
Holy b vent elbows could they have used anymore lol
2022-02-28 04:33:45
1
lipdawg
lipdawg :
is it me or does someone else think they can get another dbl wall 90 in there
2022-02-27 16:29:40
1
zekee1791
Zekee :
Shouldn’t you use brass fittings from tank to copper?
2022-02-27 14:17:10
1
bobbyberger1951
bobbyberger1951 :
think I would have changed the vent pipe to
2022-02-27 14:32:54
1
jackhammer42
Jack Hammer :
Just curious, in your state do they want dielectric adapters on the heater???
2022-02-27 19:03:41
0
boilerbob65
BoilerBob65 :
What? No Spill Switch on the stack??
2022-02-27 14:31:08
0
jmurr223
Jon :
Why are expansion tanks used sometimes? I don’t even know what they’re really for.
2022-02-27 14:20:23
0
thisguyritehere
thisguyritehere :
could have used a flex water line....works faster
2022-02-27 14:17:33
0
tiny.805
tiny.805 :
u forgot the valve's
2022-02-27 15:56:25
0
hacksaw69er
Jagoffasaurous :
Nice job 🤣🤥
2022-02-27 15:56:40
0
richardwalsh1
Richard Walsh :
we use flex lines but I'm in California. Earthquakes
2022-02-27 16:14:02
0
ryan54556
Ryan :
Why not install the pump right off the heater?
2022-02-27 16:20:03
0
tinfoilhat25
Christopher Mongeur :
No mixing valve or shutoff on the cold side? Why did you add the circulator
2022-02-27 14:14:01
0
robertoacodiaz
Big Beto. :
No valve on the cold and no unions?
2022-02-27 17:39:53
0
hustle_the_emt
Lee :
Why not use flex lines? Just curious
2022-02-27 18:32:15
0
idighips
Joe :
OMG, someone who solders!
2022-02-27 20:32:06
0
rick_h4
Rick :
if you tried, you might have been able to squeeze another fitting or two on the vent flue
2022-02-27 21:15:08
0
jeremykathleensherren
Plumbing is life :
I'm so glad there's no propress it has it's place just like shark bite
2022-02-27 21:57:16
0
ambitionplumbing19
Master plumber :
You can’t hook up copper on galvanized there has to be a union or washer to separate the 2 different types of metals. # 1 plumbing mistake.
2022-02-27 23:15:37
0
stj860
stj860 :
finally a plumber that knows how to solder 😁
2022-02-27 23:45:33
0
craigbudd927
craigbudd927 :
is that flue safe?
2022-02-27 23:53:47
0
1956topdog
T.D. :
good job man (;I'm a retired plumber)
2022-02-28 01:06:35
0
edgardrodriguez3359
Tony Rodriguez :
resurc should be on the cold side also check valves
2022-02-28 01:21:56
0
jimmymes
Jam mes :
What is the blue thing?
2022-02-28 03:03:59
0
furiouscdawg01
Skip :
See we use to do that but now if we don’t use unions at the heater they fail us. Plus they now look for a grounding wire on water/ gas lines. 2k$
2022-02-27 13:33:46
0
dracoriot4100
DracoRiot4100 :
I'm diggin it.
2022-02-28 19:53:58
0
jamiefred2
jamiefred2 :
You didn’t use the required amount of vent elbows.
2022-03-06 01:16:23
0
704plumber
704plumber :
Looks good bro
2022-04-05 11:04:11
0