@inspectiontherapy: In situations like this, it’s wise to call an engineer. #fyp #fypシ #framing #DIY #fail #construction #build #roof #structure #engineer #engineering #code #inspectedrejected #inspectedaccepted #inspectiontherapy #homeinspection #homeinspector #insulation #strong #new #realestate #wow #reinforced
Inspection Therapy
Region: US
Thursday 04 May 2023 21:53:05 GMT
Music
Download
Comments
Nick :
I'm not an inspector nor an engineer and I know that was messed up
2023-05-20 18:31:55
29
Maaaahky Maaahk :
Except that you don’t need to add anything to the frame in order to meet code with existing buildings.
2023-05-21 21:14:30
1
corradocolangelo :
What the fuck is that
2023-05-05 00:42:00
14
Chris Bennett7427 :
I'm surprised u didn't say anything about the nails not in the side of the hurricane tie
2023-05-04 22:51:16
120
DeeDNDeeD :
All he had to do was add a stand-off wall, double plate and point load the rafters over the studs.
2023-05-04 22:09:04
37
Dennis Gav :
Most of the stress on a rafter is not at the connection but towards the middle, that would've stood for another 200 years
2023-05-21 21:28:48
6
TonyChivy :
I would have never pulled a permit 😂
2023-05-21 21:23:53
4
Inspector Preston :
Inspection Perfected. TM
(I own that tagline and want royalties if you use it!)
2023-05-07 10:52:12
4
simultaneously.wathatmean :
Question is why didn’t he cut in seats. Seems hella lazy
2023-05-06 02:37:30
4
Ocholobbo :
Guess there ok with the mold and all that haha
2023-05-20 21:15:07
3
ericpreciado9448 :
This is awesome. You showed us the issue and then gave us a solution. I’m buying that shirt now
2023-05-05 19:38:12
3
user3908721476981 :
I would say fire them and start over
2023-05-21 19:24:14
2
Waitinonthebus :
adding to the wall depth means you could have run a horizontal board across the top under the rafters
2023-05-05 11:13:33
2
skydiving life :
no that was ok
2023-05-20 22:15:10
2
Yoyo :
Great post
2023-05-05 00:01:48
2
smalltownbuilders :
Easy way, just a experienced carpenter 👍🍺
2023-05-06 19:48:38
2
Tha_Allen :
love it. happy to be the first
2023-05-04 21:57:12
2
Ray Perez :
YES ,,MIGH DO FOR A CHICKEN COOP
2023-05-15 05:07:09
2
oh yes :
personally I would put uprights under the wall connections as the wall thickens needed increasing any way
2023-06-15 12:35:41
1
░m░a░t░t░e • Friend :
it'll save them money long term
2023-05-05 05:22:56
1
jreez98 :
is this in fredericton nb, i think i worked in that shack 😁
2023-05-04 22:31:43
1
Andrew Bennett :
Would spray foam insulation allow for you to not need the increased in stud bay depth?
2023-05-20 20:57:08
1
gogo :
contractor should be taken out and whipped. what is this mess.
2023-05-21 05:11:30
1
Cowboy 153 :
Me personally, might have considered notching the addons to fit over 2x4’s to start with.
2023-05-08 02:17:17
1
Stuart 1973 🇦🇺 :
they just fix the house up and don't get it inspected in Australia
2023-05-06 06:18:50
1
cthepointe :
maybe not for structure but just for added r value in the ceiling
2023-05-05 12:24:53
1
Mr Pankake 32 :
the mold on the deck ..?
2023-05-05 10:02:22
1
Michael Howe :
Shocked that passed without a lvl in the ceiling for the new 2x10s to go into.
2023-05-05 23:39:28
1
Notorious JJB :
definitely could be better but it's def a bitch to bring up a 1900's house to code
2023-05-05 13:25:17
1
fishbed_frogger :
nice work 👍
2023-05-05 22:47:43
1
Louder12 :
Must be a nice painter
2023-05-05 21:55:55
1
Nero :
What a hack work!
2023-05-05 18:51:34
1
Justin :
why would u pull a permit for an interior renovation
2023-05-06 01:53:12
0
decimus :
why didn't they just nail the new rafters to the added studs?
2023-05-05 07:43:59
0
scooter :
What does an engineer cost?
2023-05-05 16:51:53
0
KC :
You know they could’ve done it with the bird mouth and saved money. SMH ppl “it’s not my job” ugh I hate them types
2023-05-05 17:03:12
0
327 :
Someone needs to ask sparky for advice 😂
2023-05-05 17:26:37
0
Mark Fuentez752 :
No bueno😳
2023-05-05 17:57:32
0
Harry Walker886 :
That happens when the inspector don’t like the stepsister. But could make out with a sister.
2023-05-05 18:35:52
0
Diego :
They just builded a new house in to the old house 😀
2023-05-05 14:54:34
0
Asen Dinev :
missing structural nail plate on the 3" plumbing pipe, that goes true the top plate, You shouldn't pass that on framing!!!
2023-05-05 20:39:31
0
OSHA Regulations :
Had an engineer look at it 😂😂😂. Its a fucking shed.
2023-05-05 14:54:11
0
Starlight868324 :
contractors are so lame and are being replaced my immigrants daily that have higher standards
2023-05-05 22:19:51
0