@moral_lads: Replying to @Big80bus

moral_lads
moral_lads
Open In TikTok:
Region: AU
Sunday 23 June 2024 04:45:54 GMT
40257
1364
37
14

Music

Download

Comments

jeffbrooker8
jeffbrooker8 :
and sorry for starting this lol 😆
2024-06-23 05:38:21
1
bigdawwwg8
bigdawwwg8 :
100mm stormy every time n reduce for down pipe
2024-06-23 07:14:58
33
wrecker_8
Wrecker96_ :
Lay 100mm in the ground then goimg up reducer it
2024-06-23 05:07:39
55
brendankrueger3
Brendan Krueger818 :
90 isn’t for in the ground. 100 in the ground and 90 above ground
2024-06-23 05:44:53
19
brock_7637
Davo :
It’s not about being strong you want the smooth pipe so it doesn’t collect dirt
2024-06-23 05:12:57
3
tom_venner123
Tom vm :
Where do you get the stormflex? Reece?
2024-06-23 05:29:11
3
imtheking987123
SaDdS :
only lay 100mm in ground
2024-06-23 08:29:02
2
jbbrown42
JB :
❤ you put the haters to bed bhaaa
2024-06-23 06:01:24
1
luke.kernahan
Luke Kernahan :
Regardless of which is better I like how you’re trying to think for yourself and doing your own testing
2024-06-23 05:45:12
1
markandrewadams81
markandrewadams81 :
Ok, that’s surprising , I till think everything in ground should be DWV 100 PVC all the way
2024-06-23 08:00:49
1
danielrobinson929
Daniel Robinson :
In qld do u install stormwater soakwell
2024-06-23 07:34:30
0
ripdose
RIPDOSE :
150mm OPTIM DWV with solvent joints 😍 use waste pipe insted of stormwater, ideal asf 👍
2024-06-23 08:30:00
0
bmkbrav
Bmkbrav :
100mm is the standard
2024-06-23 21:12:24
0
onya_bike_mate
Top 10 Clips :
they are teaching in tafe to use 100mm opposed to 100mm just because of longevity and rigity as 90mm will bow
2024-06-24 10:07:23
0
keeganmatias
Keegan Matias :
Get an inpipe fitting for it
2024-06-23 05:46:30
0
kymhamish942
kym942 :
Having your rain fall up there, you'd think you would do it in 100mm DWV like we do in SA
2024-07-01 03:54:18
0
robertjohnson46607
robertjohnson46607 :
NSW seen stormflex once. All inground stormy should be 100mmpvc aggy for behind retaining walls etc
2024-06-24 00:40:35
0
geemanpin
Graham John Pinnell :
Question is why don’t they make a 100mm dwv x 100x50 downpipe adapter then you could run 100 mil all the way to the downpipe
2024-06-23 05:28:03
0
mitchwilson14
Mitch Wilson :
Who installs 90mm in the ground? 90 is a nice finish for downpipes and that’s it
2024-06-23 11:23:03
0
jeffbrooker8
jeffbrooker8 :
only ever put 100mm pipe 90 is terrible
2024-06-23 05:36:27
1
jbbrown42
JB :
Tell me why does Stratco flog 80 ml pipe when most use 90mm
2024-06-23 06:02:55
0
jacksonf15
Jackson :
Stormflex is rubbish just admit defeat
2024-06-23 05:00:34
4
mattyeightysixer
Mattyeightysixer :
Can you run an eel or jetter through that flexi crap? Or is it to brittle
2024-07-16 05:36:07
0
mylittlethreads
My Little Threads - MLT :
random question totally not related to this video 😂 but do you guys do rough ins?
2024-06-23 12:47:09
0
canigiveyoumy2cents
CanIGiveYouMy2Cents :
100 DWV is what plumbers use. . . Fk your 90mm. . .
2024-06-23 09:17:53
0
To see more videos from user @moral_lads, please go to the Tikwm homepage.